| Peak
Current |
|
| Range |
0 to 99.9 kiloamps |
| Over-range |
display shows "99.9" |
| Resolution |
0.1 kiloamp |
| Repeatability |
within 0.1 kiloamp |
| Accuracy |
±3% of
reading + 1 digit |
| Maximum dI/dt |
20 mega-amps/sec |
| |
|
| Duration |
|
| Range |
0 to 199.9 milliseconds |
| Over-range |
display shows "199.9" |
| Resolution |
0.1 millisecond |
| Repeatability |
within 0.1 millisecond |
| Accuracy |
±3% of
reading + 1 digit |
| |
|
| Output |
|
| Type |
Isolated
SPDT relays
|
| Contact Rating |
10
AMPS@115VAC or @24VDC resistive
|
| |
|
| Power |
|
| Line Voltage |
115VAC ± 10VAC,
50 to 400 HZ
|
| Current |
<< 1
AMP
|
| Fuse type |
5x20
mm, 1/2 AMP fast-acting
|
| |
|
| Dimensions |
|
| Current probe |
2.8" ID
toroid |
| Display unit |
|
| Overall |
12" x
10" x 5" |
| Mounting
holes |
8" x 12-3/4" (5/16" dia.
4 places) |
| |
|
| Display |
|
| Type |
Dual Liquid Crystal
Displays (LCD) |
| Backlighting |
Electroluminescent
(EL) |
| Polarity |
Displays minus
sign on negative shot only |